Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable

Model NO.: 0.6/1KV copper power cable
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE, RoHS, UL, VDE
Model: XLPE Power Cable
Brand: Chan Qing Teng
Product Name: 0.6/1kv Copper Power Cable
Rated Voltage: 0.6/1 Kv
Conductor: Copper
Insulation: XLPE / PVC
Sheath: PVC
Core Number: 1 2 3 4 5
Color Color: Red , Yellow , Blue ,Green or as Your Requirement
Origine: Shandong , China
Packaging: Wooden Drum
Shipping: 3-10 Working Days
Trademark: Luxing
Transport Package: Wooden Drum / Steel Wooden Drum
Specification: According to different cable size
Origin: Shandong, China
HS Code: 8544492100
Model NO.: 0.6/1KV copper power cable
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE, RoHS, UL, VDE
Model: XLPE Power Cable
Brand: Chan Qing Teng
Product Name: 0.6/1kv Copper Power Cable
Rated Voltage: 0.6/1 Kv
Conductor: Copper
Insulation: XLPE / PVC
Sheath: PVC
Core Number: 1 2 3 4 5
Color Color: Red , Yellow , Blue ,Green or as Your Requirement
Origine: Shandong , China
Packaging: Wooden Drum
Shipping: 3-10 Working Days
Trademark: Luxing
Transport Package: Wooden Drum / Steel Wooden Drum
Specification: According to different cable size
Origin: Shandong, China
HS Code: 8544492100

Operating Characteristics
Rated voltage: 0.6/1(1.2)kV

Max. permissible continuous operating temperature of conductor: 70oC

Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 

Nominal cross section of conductor ≤300mm2: 160 oC;

Nominal cross section of conductor >300mm2: 140 oC

The ambient temperature under installation should not be lower than: 0 oC

The bending radius of cable is recommended as following:

For single core cable: not less than 20 times of the diameter of cable

For multi-core cable: not less than 15 times of the diameter of cable
 

Application

The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or in conduit, unable to bear external mechanical force. 
 

Manufacturing Standards

GB/T 12706-2008, IEC 60502-1
 

Description

 Type Description No. of cores Nominal cross section of conductor
VV Copper conductor/PVC insulation/PVC outer sheath Power Cable 1, 2, 3, 4, 3+1, 
5, 4+1, 3+2
1.5~800mm2
VY Copper conductor/PVC insulation/PE outer sheath Power Cable 1, 2, 3, 4, 3+1, 
5, 4+1, 3+2
1.5~800mm2
ZA-VV ZB-VV ZC-VV Copper conductor/PVC insulation flame-retardant Power Cable 1, 2, 3, 4, 3+1, 
5, 4+1, 3+2
1.5~630mm2
NH-VV Copper conductor/PVC insulation fire-resistant Power Cable 1, 2, 3, 4, 3+1, 
5, 4+1, 3+2
1.5~800mm2

Specifications and Names

Type

Designation

Copper conductor

Aluminium conductor

YJV

YJLV

XLPE insulated and PVC sheathed power cable

YJV22

YJLV22

XLPE insulated, steel tape armored and PVC sheathed power cable

YJV23

YJV23

XLPE insulated, steel tape armored and PE sheathed power cable.

YJV32

YJLV32

XLPE insulated, steel wire armored and PVC sheathed power cable.

YJV33

YJV33

XLPE insulated, steel wire armored and PE sheathed power cable.

 Production Range of Cable 

TYPE

Number of cores

Rated Voltage (U0/U)kV

6/6

6/10 8.7/10

8.7/15 12/20

18/20 21/35 26/35

Nominal cross-section area of conductor  
mm2

YJV YJV32(42)

1

25~630

25~630

25~400

50~500

YJLV YJLV32(42)

35~630

35~630

35~300

50~630

YJV22

25~500

25~500

35~500

-

YJLV22

35~500

35~500

35~500

-

YJV YJV22

3

25~300

25~300

35~300

50~300

YJLV YJLV22

35~300

35~300

35~300

50~300

YJV32 YJLV32

25~300

35~300

35~300

50~300

YJV42 YJLV42

35~185

35~185

35~150

50~300

*Note:The single-core armoured cables are used for d.c.system only, as for a.c.system, non-magnetic aromour material should be used or a magnetic isolation should be applied

We also can manufacture many other specifications, if you have interest, welcome your enquiry! Everything we do is trying to make your business more successful.

Luxing Factory : our production base 
Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable

Luxing Cable Mainly Produce 

300/500V 450/750V electrical wire  AAC conductor 
600/1000V PVC insulated cable AAAC conductor 
600/1000V XLPE insulated cable ACSR conductor 
1.8/3KV to 26/35KV power cable  OPGW 
Armored underground cable ABC cable 
Control cable and instrumentation cables  Rubber cable

Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable

Certificates 
Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable

Strict Quality Test 
Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable

Packaging & Shipping

Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable

Why choose us 

1.18 years manufacturing experience

2.Professional international trade team

3.Delivery on time

4.Factory low price and high quality based on advanced technology and high work efficiency
 

Contact us 

Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable
 

Operating Characteristics
Rated voltage: 0.6/1(1.2)kV

Max. permissible continuous operating temperature of conductor: 70oC

Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 

Nominal cross section of conductor ≤300mm2: 160 oC;

Nominal cross section of conductor >300mm2: 140 oC

The ambient temperature under installation should not be lower than: 0 oC

The bending radius of cable is recommended as following:

For single core cable: not less than 20 times of the diameter of cable

For multi-core cable: not less than 15 times of the diameter of cable
 

Application

The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or in conduit, unable to bear external mechanical force. 
 

Manufacturing Standards

GB/T 12706-2008, IEC 60502-1
 

Description

 Type Description No. of cores Nominal cross section of conductor
VV Copper conductor/PVC insulation/PVC outer sheath Power Cable 1, 2, 3, 4, 3+1, 
5, 4+1, 3+2
1.5~800mm2
VY Copper conductor/PVC insulation/PE outer sheath Power Cable 1, 2, 3, 4, 3+1, 
5, 4+1, 3+2
1.5~800mm2
ZA-VV ZB-VV ZC-VV Copper conductor/PVC insulation flame-retardant Power Cable 1, 2, 3, 4, 3+1, 
5, 4+1, 3+2
1.5~630mm2
NH-VV Copper conductor/PVC insulation fire-resistant Power Cable 1, 2, 3, 4, 3+1, 
5, 4+1, 3+2
1.5~800mm2

Specifications and Names

Type

Designation

Copper conductor

Aluminium conductor

YJV

YJLV

XLPE insulated and PVC sheathed power cable

YJV22

YJLV22

XLPE insulated, steel tape armored and PVC sheathed power cable

YJV23

YJV23

XLPE insulated, steel tape armored and PE sheathed power cable.

YJV32

YJLV32

XLPE insulated, steel wire armored and PVC sheathed power cable.

YJV33

YJV33

XLPE insulated, steel wire armored and PE sheathed power cable.

 Production Range of Cable 

TYPE

Number of cores

Rated Voltage (U0/U)kV

6/6

6/10 8.7/10

8.7/15 12/20

18/20 21/35 26/35

Nominal cross-section area of conductor  
mm2

YJV YJV32(42)

1

25~630

25~630

25~400

50~500

YJLV YJLV32(42)

35~630

35~630

35~300

50~630

YJV22

25~500

25~500

35~500

-

YJLV22

35~500

35~500

35~500

-

YJV YJV22

3

25~300

25~300

35~300

50~300

YJLV YJLV22

35~300

35~300

35~300

50~300

YJV32 YJLV32

25~300

35~300

35~300

50~300

YJV42 YJLV42

35~185

35~185

35~150

50~300

*Note:The single-core armoured cables are used for d.c.system only, as for a.c.system, non-magnetic aromour material should be used or a magnetic isolation should be applied

We also can manufacture many other specifications, if you have interest, welcome your enquiry! Everything we do is trying to make your business more successful.

Luxing Factory : our production base 
Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable

Luxing Cable Mainly Produce 

300/500V 450/750V electrical wire  AAC conductor 
600/1000V PVC insulated cable AAAC conductor 
600/1000V XLPE insulated cable ACSR conductor 
1.8/3KV to 26/35KV power cable  OPGW 
Armored underground cable ABC cable 
Control cable and instrumentation cables  Rubber cable

Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable

Certificates 
Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable

Strict Quality Test 
Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable

Packaging & Shipping

Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable

Why choose us 

1.18 years manufacturing experience

2.Professional international trade team

3.Delivery on time

4.Factory low price and high quality based on advanced technology and high work efficiency
 

Contact us 

Underground Low Voltage 0.6/1kv Copper Conductor XLPE Electric Power Cable
 

Solar Hybrid Inverter

Pure sine ware output

Optional MPPT/PWM solar charge controller 60A

MPPT Efficiency max 98%

DC Start & Automatic Self-Diagnostic Function

solar inverter for power system

On/Off Grid Solar Inverter,Hybrid Inverter With Mppt Charge,pure sine wave solar inverter

suzhou whaylan new energy technology co., ltd , https://www.whaylanenergy.com