(1) M method: It is to count the number of output pulses of the photoelectric code disc in a certain time interval, and calculate the rotation speed, which is suitable for high-speed measurement of the generator speed.
(2) T method: It is a measurement method for calculating the motor speed by measuring the pulse period of the photoelectric code disk.
(3) M/T method: It combines the advantages of M method and T method, and has high resolution and measurement accuracy in low speed and high speed sections.
(4) E/T method: The principle is to start from the T method, just to overcome the accuracy problem of the T method at high speed.
Combining plc with the speed measurement range of the hydropower generating unit (0~600r/min) and the simpleness of the M method for measuring the speed, the M method is used to measure and calculate the speed.
Assuming that the photoelectric code disk coaxially connected to the generator rotates once a week, the number of output pulses is P, the rotational speed of the motor is n (r/min), the detection time is T(s), and the number of counting pulses in T is m. Then the speed n of the motor is: n = 60m/pt
In the detection time T, the error is at most 1 pulse, then the M method speed resolution Q is: Q = 60 (m + 1) / pt - 60m / pt = 60 / pt
It can be seen that when using the M method to measure the speed, the resolution is independent of the magnitude of the speed. In order to improve the resolution, except for the optoelectronic code disc with a large number of output pulses per revolution, only the detection time is increased as much as possible, but the detection time is too large. The more severe the feedback delay of the speed, the serious impact on the dynamic and static performance of the system.

KNL4-100 Residual Current Circuit Breaker

KNL4-100 Moulded Case Circuit Breaker is MCCB , How to select good Molded Case Circuit Breaker suppliers? Korlen electric is your first choice. All moulded Case Circuit Breakers pass the CE.CB.SEMKO.SIRIM etc. Certificates.

Moulded Case Circuit Breaker /MCCB can be used to distribute electric power and protect power equipment against overload and short-current, and can change the circuit and start motor infrequently. The application of Moulded Case Circuit Breaker /MCCB is industrial.
Korlen electric also provide Miniature Circuit Breaker /MCB. Residual Current Circuit Breaker /RCCB. RCBO. Led light and so on .

KNL4-100 Molded Case Circuit Breaker,KNL4-100 Small Size Molded Case Circuit Breaker,KNL4-100 Electrical Molded Case Circuit Breaker,KNL4-100 Automatic Molded Case Circuit Breaker

Wenzhou Korlen Electric Appliances Co., Ltd. , https://www.zjmannualmotorstarter.com