Features:
* Universal AC input/full range(highest 305VAC)
*Built-in active power factor correction function
*Protection function: Short circuit,over current,over voltage, over temperature
*Efficiency highest 94%
*IP67/65 design, suitable for family installation (HLG-240H C type except)
*Output current is adjustable
*Natural cooling
*Suitable for dry,wet,wet environment
*Suitable for all kinds of LED lighting and street lighting applications
*In accordance with 4KV surge resistance level (IEC61000-4-5)
*Class 2 or 1 power/by LPS(limited power source) test (HLG-120H except)
*5 years warranty
Series No. | Model No. | Specification | |||||||||||||||
AC input range | AC inrush Current(Max.) | DC voltage adjustable range | Current adjustable range | Over current protection | Over voltage protection | Start,rise,keep time | Withstand Voltage | Working Temperature | EMC standards | Connector input/output |
Output | Voltage tolerance | Ripple&noise | Efficiency | Size(mm) | ||
HLG-150H | HLG-150H-12 | 90~305VAC;127~431VDC | Cold start, 65A/230VAC |
±10% rated output voltage (only type A) | 60%-100% | 95%~108% Set the current limit,automatic recovery | 110%~140% rated output voltage | 2500ms,80ms,16ms | I/P-O/P:3.75KVAC; I/P-FG:2KVAC; O/P-FG:0.5KVAC | -40ºC~+70ºC | EN55015,EN61000-3-2 class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11, EN61547 | Input: UL,SJTW 18AGWx3C(30cm);Output:A/D Type:SVT 18AWGx2C(30cm);B type:SJTW 14AWGx2C (30cm); B type: SJTW 14AWGx2C(30cm)+SJTW 18AWGx2C(30cm)  | 12V,0~12.5A | ±2.5% | 150mV | 91.5% | 195.6x61.5x38.8 |
HLG-150H-15 | 15V,0~10A | ±2% | 150mV | 92.0% | |||||||||||||
HLG-150H-20 | 20V,0~7.5A | ±1% | 150mV | 93.0% | |||||||||||||
HLG-150H-24 | 24V,0~6.3A | ±1% | 150mV | 93.0% | |||||||||||||
HLG-150H-30 | 30V,0~5A | ±1% | 200mV | 93.5% | |||||||||||||
HLG-150H-36 | 36V, 0~4.2A | ±1% | 200mV | 93.5% | |||||||||||||
HLG-150H-42 | 42V,0~3.6A | ±1% | 200mV | 94.0% | |||||||||||||
HLG-150H-48 | 48V,0~3.2A | ±1% | 200mV | 94.0% | |||||||||||||
HLG-150H-54 | 54V,0~2.8A | ±1% | 200mV | 94.0% | |||||||||||||
HLG-185H | HLG-185H-12 | 90~305VAC;127~431VDC | Cold start, 65A/230VAC |
±10% rated output voltage (only type A) | 50%-100% | 95%~108% Set the current limit,automatic recovery | 110%~140% rated output voltage | 2500ms,50ms,16ms | I/P-O/P:3.75KVAC; I/P-FG:2KVAC; O/P-FG:0.5KVAC | -40ºC~+70ºC | 12V,0~13A | ±2.5% | 150mV | 91.5% | 220x68x38.8 | ||
HLG-185H-15 | 15V,0~11.5A | ±2% | 150mV | 92.0% | |||||||||||||
HLG-185H-20 | 20V, 0~9.3A | ±1% | 150mV | 93.0% | |||||||||||||
HLG-185H-24 | 24V, 0~7.8A | ±1% | 150mV | 93.5% | |||||||||||||
HLG-185H-30 | 30V,0~6.2A | ±1% | 200mV | 93.5% | |||||||||||||
HLG-185H-36 | 36V,0~5.2A | ±1% | 200mV | 93.5% | |||||||||||||
HLG-185H-42 | 42V,0~4.4A | ±1% | 200mV | 94.0% | |||||||||||||
HLG-185H-48 | 48V,0~3.9A | ±1% | 200mV | 94.0% | |||||||||||||
HLG-185H-54 | 54V,0~3.45A | ±1% | 200mV | 94.0% | |||||||||||||
HLG-240H | HLG-240H-12 | 90~305VAC;127~431VDC | Cold start, 75A/230VAC |
±6% rated output voltage (only type A) | 50%-100% | 95%~108% Set the current limit,automatic recovery | 110%~140% rated output voltage | 2500ms,50ms,15ms(230VAC Full load) | I/P-O/P:3.75KVAC; I/P-FG:2KVAC; O/P-FG:0.5KVAC | -40ºC~+70ºC | 12V,0~16A | ±2.5% | 150mV | 90.0% | 220x68x38.8 | ||
HLG-240H-15 | 15V, 0~15A | ±2% | 150mV | 90.0% | |||||||||||||
HLG-240H-20 | 20V, 0~12A | ±1% | 150mV | 91.5% | |||||||||||||
HLG-240H-24 | 24V, 0~10A | ±1% | 150mV | 92.5% | |||||||||||||
HLG-240H-30 | 30V,0~8A | ±1% | 200mV | 92.5% | |||||||||||||
HLG-240H-36 | 36V,0~6.7A | ±1% | 200mV | 92.5% | |||||||||||||
HLG-240H-42 | 42V,0~5.72A | ±1% | 200mV | 92.5% | |||||||||||||
HLG-240H-48 | 48V,0~5A | ±1% | 200mV | 93.0% | |||||||||||||
HLG-240H-54 | 54V,0~4.45A | ±1% | 200mV | 93.5% |
Features:
* Universal AC input/full range(highest 305VAC)
*Built-in active power factor correction function
*Protection function: Short circuit,over current,over voltage, over temperature
*Efficiency highest 94%
*IP67/65 design, suitable for family installation (HLG-240H C type except)
*Output current is adjustable
*Natural cooling
*Suitable for dry,wet,wet environment
*Suitable for all kinds of LED lighting and street lighting applications
*In accordance with 4KV surge resistance level (IEC61000-4-5)
*Class 2 or 1 power/by LPS(limited power source) test (HLG-120H except)
*5 years warranty
Series No. | Model No. | Specification | |||||||||||||||
AC input range | AC inrush Current(Max.) | DC voltage adjustable range | Current adjustable range | Over current protection | Over voltage protection | Start,rise,keep time | Withstand Voltage | Working Temperature | EMC standards | Connector input/output |
Output | Voltage tolerance | Ripple&noise | Efficiency | Size(mm) | ||
HLG-150H | HLG-150H-12 | 90~305VAC;127~431VDC | Cold start, 65A/230VAC |
±10% rated output voltage (only type A) | 60%-100% | 95%~108% Set the current limit,automatic recovery | 110%~140% rated output voltage | 2500ms,80ms,16ms | I/P-O/P:3.75KVAC; I/P-FG:2KVAC; O/P-FG:0.5KVAC | -40ºC~+70ºC | EN55015,EN61000-3-2 class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11, EN61547 | Input: UL,SJTW 18AGWx3C(30cm);Output:A/D Type:SVT 18AWGx2C(30cm);B type:SJTW 14AWGx2C (30cm); B type: SJTW 14AWGx2C(30cm)+SJTW 18AWGx2C(30cm)  | 12V,0~12.5A | ±2.5% | 150mV | 91.5% | 195.6x61.5x38.8 |
HLG-150H-15 | 15V,0~10A | ±2% | 150mV | 92.0% | |||||||||||||
HLG-150H-20 | 20V,0~7.5A | ±1% | 150mV | 93.0% | |||||||||||||
HLG-150H-24 | 24V,0~6.3A | ±1% | 150mV | 93.0% | |||||||||||||
HLG-150H-30 | 30V,0~5A | ±1% | 200mV | 93.5% | |||||||||||||
HLG-150H-36 | 36V, 0~4.2A | ±1% | 200mV | 93.5% | |||||||||||||
HLG-150H-42 | 42V,0~3.6A | ±1% | 200mV | 94.0% | |||||||||||||
HLG-150H-48 | 48V,0~3.2A | ±1% | 200mV | 94.0% | |||||||||||||
HLG-150H-54 | 54V,0~2.8A | ±1% | 200mV | 94.0% | |||||||||||||
HLG-185H | HLG-185H-12 | 90~305VAC;127~431VDC | Cold start, 65A/230VAC |
±10% rated output voltage (only type A) | 50%-100% | 95%~108% Set the current limit,automatic recovery | 110%~140% rated output voltage | 2500ms,50ms,16ms | I/P-O/P:3.75KVAC; I/P-FG:2KVAC; O/P-FG:0.5KVAC | -40ºC~+70ºC | 12V,0~13A | ±2.5% | 150mV | 91.5% | 220x68x38.8 | ||
HLG-185H-15 | 15V,0~11.5A | ±2% | 150mV | 92.0% | |||||||||||||
HLG-185H-20 | 20V, 0~9.3A | ±1% | 150mV | 93.0% | |||||||||||||
HLG-185H-24 | 24V, 0~7.8A | ±1% | 150mV | 93.5% | |||||||||||||
HLG-185H-30 | 30V,0~6.2A | ±1% | 200mV | 93.5% | |||||||||||||
HLG-185H-36 | 36V,0~5.2A | ±1% | 200mV | 93.5% | |||||||||||||
HLG-185H-42 | 42V,0~4.4A | ±1% | 200mV | 94.0% | |||||||||||||
HLG-185H-48 | 48V,0~3.9A | ±1% | 200mV | 94.0% | |||||||||||||
HLG-185H-54 | 54V,0~3.45A | ±1% | 200mV | 94.0% | |||||||||||||
HLG-240H | HLG-240H-12 | 90~305VAC;127~431VDC | Cold start, 75A/230VAC |
±6% rated output voltage (only type A) | 50%-100% | 95%~108% Set the current limit,automatic recovery | 110%~140% rated output voltage | 2500ms,50ms,15ms(230VAC Full load) | I/P-O/P:3.75KVAC; I/P-FG:2KVAC; O/P-FG:0.5KVAC | -40ºC~+70ºC | 12V,0~16A | ±2.5% | 150mV | 90.0% | 220x68x38.8 | ||
HLG-240H-15 | 15V, 0~15A | ±2% | 150mV | 90.0% | |||||||||||||
HLG-240H-20 | 20V, 0~12A | ±1% | 150mV | 91.5% | |||||||||||||
HLG-240H-24 | 24V, 0~10A | ±1% | 150mV | 92.5% | |||||||||||||
HLG-240H-30 | 30V,0~8A | ±1% | 200mV | 92.5% | |||||||||||||
HLG-240H-36 | 36V,0~6.7A | ±1% | 200mV | 92.5% | |||||||||||||
HLG-240H-42 | 42V,0~5.72A | ±1% | 200mV | 92.5% | |||||||||||||
HLG-240H-48 | 48V,0~5A | ±1% | 200mV | 93.0% | |||||||||||||
HLG-240H-54 | 54V,0~4.45A | ±1% | 200mV | 93.5% |
EV Charging Pile energy meter 240v specializes in measuring the data of all kinds of AC networks. energy meter lcd display can be used for local display, or Energy Meter Manufacturers is connected with the control equipment in measuring and controlling system. different specification energy meters comply EN 61326:2006 and EN 61010-1:2001.
energy meter with ct are a kind of programmable analyzer. With the 2 key on the front, we can choose to read the data that we need. ct connection with energy meter can be equipped RS-485 communication Modbus-RTU.
energy meter wifi are a kind of analyzer with excellent cost performance, since energy meters online regroup the functions of traditional electric transmitter and digital meters. Therefore Energy Meter Modbus are widely being used in kinds of control system, SCADA system and power management system.
Smart Din Rail Energy Meter,Three Phase Energy Meter,Energy Meter Accuracy Class,Kwh Calculation Energy Meter
Jiangsu Acrel Electrical Manufacturing Co., LTD. , https://www.acrel.com.pk