Rvv Fire Performance Cable Fire Resistant Cables

Model NO.: RVV Fire Performance Cable
Range of Application: Flame Retardant
Certification: ISO9001, CE, CCC, RoHS
Insulation: PVC
Core: Single/Multi-Cores
Standard: IEC/NFC33-209
Quality Guarantee: 10 Years
Sheath Color: Black
Mark: Laser Type
Manufacture: Yes
Sample: Yes
Cable Parts: Yes
Conductor: Copper/Al Core
Trademark: Hongda
Transport Package: Wooden Plate
Specification: 1.5-630sqmm
Origin: China, Henan
HS Code: 8544492100
Model NO.: RVV Fire Performance Cable
Range of Application: Flame Retardant
Certification: ISO9001, CE, CCC, RoHS
Insulation: PVC
Core: Single/Multi-Cores
Standard: IEC/NFC33-209
Quality Guarantee: 10 Years
Sheath Color: Black
Mark: Laser Type
Manufacture: Yes
Sample: Yes
Cable Parts: Yes
Conductor: Copper/Al Core
Trademark: Hongda
Transport Package: Wooden Plate
Specification: 1.5-630sqmm
Origin: China, Henan
HS Code: 8544492100

Our fire resistant cable range is designed to ensure that emergency systems in public buildings continue to operate in some of the most extreme fire conditions.

 

Fire Performance cable products

Our fire performance cables are specifically designed for augmented fire resistance in applications including the delivery of power and auxiliary control in fire alarm systems, voice alarm systems, and emergency lighting systems including those applications designed to meet BS5266. These cables will form part of the requirements of BS8519 for the installation of fire-resistant power and control cable systems for life safety and fire-fighting applications.

These fire resistant single core and multi-core cables are suitable for use within a number of Control Circuit categories. For added protection against the risk of mechanical damage, we supply robust Firetec 'Power' and 'Impact Power' cables, both of which are suitable for indoor and outdoor applications. The 'Impact Power' is designed to withstand direct impact and water jet pressure. For additional flexibility, we supply the FRF2 cable, a cable suitable for bending around complex corners and the single core Tubesafe cable as found in environments such as the London Underground network.

Other fire resistant cables in our fire performance range include Mineral Insulated copper cables (MICC), designed to offer the ultimate fire resistance and good protection against electromagnetic interference. These high temperature cables are manufactured without any plastic insulation and provide circuit integrity up to 950oC. They are also available with LSZH oversheathing in various colour options. These cables are principally used within hazardous and explosive environments or where corrosive chemicals may affect performance. The LSZH insulated cables hold LPCB-approval. Those without polymer oversheathing have ATEX approval and comply with the EU directives on working within hazardous or explosive environments.
 

 

Important fire performance cable definitions

Fire resistant single core and multicore cables - PH30 / PH60 / PH120 cable - fire rated

  Fire proof cable duration Applications
PH30  Fire rated
30 minutes
PH30 cables are suitable for emergency applications where the circuit must remain operational for up to 30 minutes
PH60 Fire rated
60 minutes
(1 hour)
PH60 cables are used in emergency applications, in particular emergency lighting to BS5266 where longer circuit operation is required in the event of fire
PH120 Fire rated
120 minutes
(2 hours)
PH120 cables are designed for installations requiring enhanced circuit integrity for up to 120 minutes, This includes complex or high-rise blocks of flats requiring a longer evacuation period.


Standard fire resistance vs Enhanced fire resistance

Level Manufacturing British standard Applications
Standard fire resistance BS7629-1,
BS EN 50200 PH30, PH60 and PH120
Fire resistant single core cables and multicore cables for BS5839-1 (most fire detection and fire alarm systems), BS5266 (emergency lighting and standard application circuits), and BS8519 (life safety and fire-fighting) category 1 control circuits. Where used under standard BS5839-1, standard fire-resisting cables should be considered to provide sufficient resistance to the effects of fire, with appropriate methods of support and jointing.
Enhanced fire resistance BS7629-1, BS8434-2,
BS EN 50200 PH30, PH60 and PH120
Enhanced fire resistant cables are used in most public or complex buildings requiring emergency systems to remain operational for a minimum of two hours (PH120) in compliance with BS8434-2 and BS8519 category 1 & 2 control circuits. They are used for unsprinklered buildings with phased evacuation, unsprinklered buildings in excess of 30 metres in height, and where the designer, specifier or enforcing authority determines it is necessary on the basis of fire risk.

Fire resistant vs flame retardant cables

An important distinction exists between fire resistant cables and flame retardant cables, even though both of them are subjected to various fire performance tests in order to earn their respective classification. In brief, flame retardant cables are designed to resist the spread of fire into a new area. Fire resistant or fire rated cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions. The distinction between the two is crucial when it comes to maintaining critical circuits required for life safety or for a safe and immediate plant shutdown.

 
Fire resistant (fire rated) cables Continues to operate in the presence of fire, hence their reference as Circuit Integrity cables, This includes PH30, PH60 and PH120 cables.
Flame retardant cables Fire performance limited to not propagating fire

PVC Cable products

Eland Cables supplies a wide range of PVC cable products manufactured in accordance with various international standards. Some of the most commonly requested cables in our portfolio include:

  Application overview
Twin & Earth cable (624Y) Mains electricity wiring
Tri-rated cable Switchgear and panel wire manufactured to UL, CSA and British Standard
2491X cable (H05V-K / H07V-K) Flexible panel wire
218Y cable  (H03VV-F) Domestic and office power supply
2192Y cable (H03VVH2-F) General wiring in public areas
309Y cable (H05V2V2-F) Portable tools power supply
318Y cable (H05VV-F) Domestic appliance power supply
318A cable (Arctic grade) Low temperature resistant power supply
6381Y cable Power, lighting and internal wiring cable. Also suitable for AC and DC telecommunications applications.
Twinflex cable Battery cable
Elevator flatform cable For lifts and elevators


In addition to the electrical cables listed above and the other standard PVC wire in our portfolio, our technical engineers can help you develop a customised PVC cable solution designed and manufactured to meet your application's specific requirements.
Rvv Fire Performance Cable Fire Resistant Cables

Application

House wiring Electric wire 1.5mm 2.5mm etc is suitable for household electrical appliances, small electric power tools, instruments and apparatuses and lighting devices,  AC rated voltage up to and including 300/500V 450/700V, which is used for connecting power line.

BV/BVR Wires for Housing and Office with Good Quality

3C approval BV electrical wire cable with Copper core pvc insulasted is a fine and ideal cable with conductor of plain annealed copper wires,solid or stranded.These cables are used for general purpose,as building wire for power, lighting and control wire to electrical appliances,suitable for use in conduit and for fixed,protected installation. The cable can be of flame ratardance,fire resistance and other property.

BV cables have very good sales over the world,enjoying a very good reputation based on top quality,most competitive price and best service.


Technical Information:
1. Voltage: 300/500V,450/750V
2. Standard Applied: IEC 60227,VDE0285,GB/T 5023
3. Max.Operating Temperature: 70°C,can be 90°C,105°C as per requirment
4. Conductor:Copper wire,solid or stranded
5. Insulation:PVC
6.Range of Nominal cross section:0.50-95mm2 
7. Jacket: without Jacket
8. Color: Black,Brown,Grey,Blue,Green/Yellow or orthers on request
9.Flame ratardance,fire resistance and other property can be available
10.Packing:100 meter/roll or as per requirement
11.Certification:ISO9001,RoHS,Reach,CCC,VDE,SAA,UL,CE,etc.                                                                           12.OME can be available

Specification 

Type: Solid Type, Stranded Type, Flexible Type are available. 
Rvv Fire Performance Cable Fire Resistant Cables

 

Size: 0.5-630mm2 , BV BVV BVR RV RVV,RVS

Length: 100M 200M 300M 500M/roll, Can make as your request.
 

Type Cross Section(mm2) Conductor Size(No. of Cores/Diameter) Rated Voltage Nominal Insulation Thickness(mm) Reference Weight(kg/km) Application
Solid Type 0.5 1/0.80

300/500V

450/750V

0.6 8.0 Solid, Hard,Suitable for fixed installation
0.75 1/0.97 0.6 11.4
1 1/1.13 0.6 15.2
1.5 1/1.38 0.7 21
2.5 1/1.78 0.7 32
4 1/2.25 0.8 47
6 1/2.76 0.8 67
Stranded Type 1.5 7/0.52 0.7 22 Stranded, Flexible house wiring, Suitable for indoor applicant.
2.5 7/0.68 0.7 35
2.5 19/0.40 0.8 34
4 7/0.85 0.8 50
4 19/0.52 0.8 51
6 7/1.04 0.8 71
6 19/0.64 0.8 72
10 7/1.35 1.0 118
10 49/0.52 1.0 127
16 7/1.70 1.0 177
16 49/0.64 1.0 184
Flexible Type 1.5 30/0.25 0.7 22 Ultra Flexible, Soft Conductor, Suitable for small power equipment instrument.
2.5 49/0.25 0.8 34
4 56/0.30 0.8 49
6 84/0.30 0.8 70
10 77/0.40 1.0 117
16 119/0.40 1.0 168
25 189/0.40 1.2 265
...      

  The cable can be of flame retardance, fire resistance, environment friendly or other property. OEM Available.

Parameter

1.Voltage Uo/U 300/500V 450/750V
2.Max. Permissible Continuous Operation Temperature of The Conductor: 70°C
   Flame-retardant Can be reach 90°C or 105°C

3.The Ambient Temperature Under Installation Should Not Below 0°C
4.Impedance (ohms): 100±2ohm


Packaging&Delivery
Rvv Fire Performance Cable Fire Resistant CablesRvv Fire Performance Cable Fire Resistant Cables

 

Packaging Details: Packing Length:100m/roll, 200m/roll, 305m/roll, 500m/roll
Delivery Time:Normally within 10 days (detailly depend on the order quantity)

 Contact us

Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software. 
 Tel :+86 15039132763  

Our fire resistant cable range is designed to ensure that emergency systems in public buildings continue to operate in some of the most extreme fire conditions.

 

Fire Performance cable products

Our fire performance cables are specifically designed for augmented fire resistance in applications including the delivery of power and auxiliary control in fire alarm systems, voice alarm systems, and emergency lighting systems including those applications designed to meet BS5266. These cables will form part of the requirements of BS8519 for the installation of fire-resistant power and control cable systems for life safety and fire-fighting applications.

These fire resistant single core and multi-core cables are suitable for use within a number of Control Circuit categories. For added protection against the risk of mechanical damage, we supply robust Firetec 'Power' and 'Impact Power' cables, both of which are suitable for indoor and outdoor applications. The 'Impact Power' is designed to withstand direct impact and water jet pressure. For additional flexibility, we supply the FRF2 cable, a cable suitable for bending around complex corners and the single core Tubesafe cable as found in environments such as the London Underground network.

Other fire resistant cables in our fire performance range include Mineral Insulated copper cables (MICC), designed to offer the ultimate fire resistance and good protection against electromagnetic interference. These high temperature cables are manufactured without any plastic insulation and provide circuit integrity up to 950oC. They are also available with LSZH oversheathing in various colour options. These cables are principally used within hazardous and explosive environments or where corrosive chemicals may affect performance. The LSZH insulated cables hold LPCB-approval. Those without polymer oversheathing have ATEX approval and comply with the EU directives on working within hazardous or explosive environments.
 

 

Important fire performance cable definitions

Fire resistant single core and multicore cables - PH30 / PH60 / PH120 cable - fire rated

  Fire proof cable duration Applications
PH30  Fire rated
30 minutes
PH30 cables are suitable for emergency applications where the circuit must remain operational for up to 30 minutes
PH60 Fire rated
60 minutes
(1 hour)
PH60 cables are used in emergency applications, in particular emergency lighting to BS5266 where longer circuit operation is required in the event of fire
PH120 Fire rated
120 minutes
(2 hours)
PH120 cables are designed for installations requiring enhanced circuit integrity for up to 120 minutes, This includes complex or high-rise blocks of flats requiring a longer evacuation period.


Standard fire resistance vs Enhanced fire resistance

Level Manufacturing British standard Applications
Standard fire resistance BS7629-1,
BS EN 50200 PH30, PH60 and PH120
Fire resistant single core cables and multicore cables for BS5839-1 (most fire detection and fire alarm systems), BS5266 (emergency lighting and standard application circuits), and BS8519 (life safety and fire-fighting) category 1 control circuits. Where used under standard BS5839-1, standard fire-resisting cables should be considered to provide sufficient resistance to the effects of fire, with appropriate methods of support and jointing.
Enhanced fire resistance BS7629-1, BS8434-2,
BS EN 50200 PH30, PH60 and PH120
Enhanced fire resistant cables are used in most public or complex buildings requiring emergency systems to remain operational for a minimum of two hours (PH120) in compliance with BS8434-2 and BS8519 category 1 & 2 control circuits. They are used for unsprinklered buildings with phased evacuation, unsprinklered buildings in excess of 30 metres in height, and where the designer, specifier or enforcing authority determines it is necessary on the basis of fire risk.

Fire resistant vs flame retardant cables

An important distinction exists between fire resistant cables and flame retardant cables, even though both of them are subjected to various fire performance tests in order to earn their respective classification. In brief, flame retardant cables are designed to resist the spread of fire into a new area. Fire resistant or fire rated cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions. The distinction between the two is crucial when it comes to maintaining critical circuits required for life safety or for a safe and immediate plant shutdown.

 
Fire resistant (fire rated) cables Continues to operate in the presence of fire, hence their reference as Circuit Integrity cables, This includes PH30, PH60 and PH120 cables.
Flame retardant cables Fire performance limited to not propagating fire

PVC Cable products

Eland Cables supplies a wide range of PVC cable products manufactured in accordance with various international standards. Some of the most commonly requested cables in our portfolio include:

  Application overview
Twin & Earth cable (624Y) Mains electricity wiring
Tri-rated cable Switchgear and panel wire manufactured to UL, CSA and British Standard
2491X cable (H05V-K / H07V-K) Flexible panel wire
218Y cable  (H03VV-F) Domestic and office power supply
2192Y cable (H03VVH2-F) General wiring in public areas
309Y cable (H05V2V2-F) Portable tools power supply
318Y cable (H05VV-F) Domestic appliance power supply
318A cable (Arctic grade) Low temperature resistant power supply
6381Y cable Power, lighting and internal wiring cable. Also suitable for AC and DC telecommunications applications.
Twinflex cable Battery cable
Elevator flatform cable For lifts and elevators


In addition to the electrical cables listed above and the other standard PVC wire in our portfolio, our technical engineers can help you develop a customised PVC cable solution designed and manufactured to meet your application's specific requirements.
Rvv Fire Performance Cable Fire Resistant Cables

Application

House wiring Electric wire 1.5mm 2.5mm etc is suitable for household electrical appliances, small electric power tools, instruments and apparatuses and lighting devices,  AC rated voltage up to and including 300/500V 450/700V, which is used for connecting power line.

BV/BVR Wires for Housing and Office with Good Quality

3C approval BV electrical wire cable with Copper core pvc insulasted is a fine and ideal cable with conductor of plain annealed copper wires,solid or stranded.These cables are used for general purpose,as building wire for power, lighting and control wire to electrical appliances,suitable for use in conduit and for fixed,protected installation. The cable can be of flame ratardance,fire resistance and other property.

BV cables have very good sales over the world,enjoying a very good reputation based on top quality,most competitive price and best service.


Technical Information:
1. Voltage: 300/500V,450/750V
2. Standard Applied: IEC 60227,VDE0285,GB/T 5023
3. Max.Operating Temperature: 70°C,can be 90°C,105°C as per requirment
4. Conductor:Copper wire,solid or stranded
5. Insulation:PVC
6.Range of Nominal cross section:0.50-95mm2 
7. Jacket: without Jacket
8. Color: Black,Brown,Grey,Blue,Green/Yellow or orthers on request
9.Flame ratardance,fire resistance and other property can be available
10.Packing:100 meter/roll or as per requirement
11.Certification:ISO9001,RoHS,Reach,CCC,VDE,SAA,UL,CE,etc.                                                                           12.OME can be available

Specification 

Type: Solid Type, Stranded Type, Flexible Type are available. 
Rvv Fire Performance Cable Fire Resistant Cables

 

Size: 0.5-630mm2 , BV BVV BVR RV RVV,RVS

Length: 100M 200M 300M 500M/roll, Can make as your request.
 

Type Cross Section(mm2) Conductor Size(No. of Cores/Diameter) Rated Voltage Nominal Insulation Thickness(mm) Reference Weight(kg/km) Application
Solid Type 0.5 1/0.80

300/500V

450/750V

0.6 8.0 Solid, Hard,Suitable for fixed installation
0.75 1/0.97 0.6 11.4
1 1/1.13 0.6 15.2
1.5 1/1.38 0.7 21
2.5 1/1.78 0.7 32
4 1/2.25 0.8 47
6 1/2.76 0.8 67
Stranded Type 1.5 7/0.52 0.7 22 Stranded, Flexible house wiring, Suitable for indoor applicant.
2.5 7/0.68 0.7 35
2.5 19/0.40 0.8 34
4 7/0.85 0.8 50
4 19/0.52 0.8 51
6 7/1.04 0.8 71
6 19/0.64 0.8 72
10 7/1.35 1.0 118
10 49/0.52 1.0 127
16 7/1.70 1.0 177
16 49/0.64 1.0 184
Flexible Type 1.5 30/0.25 0.7 22 Ultra Flexible, Soft Conductor, Suitable for small power equipment instrument.
2.5 49/0.25 0.8 34
4 56/0.30 0.8 49
6 84/0.30 0.8 70
10 77/0.40 1.0 117
16 119/0.40 1.0 168
25 189/0.40 1.2 265
...      

  The cable can be of flame retardance, fire resistance, environment friendly or other property. OEM Available.

Parameter

1.Voltage Uo/U 300/500V 450/750V
2.Max. Permissible Continuous Operation Temperature of The Conductor: 70°C
   Flame-retardant Can be reach 90°C or 105°C

3.The Ambient Temperature Under Installation Should Not Below 0°C
4.Impedance (ohms): 100±2ohm


Packaging&Delivery
Rvv Fire Performance Cable Fire Resistant CablesRvv Fire Performance Cable Fire Resistant Cables

 

Packaging Details: Packing Length:100m/roll, 200m/roll, 305m/roll, 500m/roll
Delivery Time:Normally within 10 days (detailly depend on the order quantity)

 Contact us

Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software. 
 Tel :+86 15039132763  

High Mast Lighting

High Mast Lighting,Airport High Mast Lighting,Air Port High Mast Lighting

Huayuan Lighting Co., Ltd. , http://www.jslightpoles.com