Product Features
© Reduce the starting current, reduce power supply peak current, reduce the cost of distribution equipment. Reduce the abrasion of motor, improve the service life of mechanical equipment.
© Optional starting parameters are convenient in one soft starter starting different motors.
© Soft starter inspects motor feedback voltage to realize closed loop control, ensure the motor start-up success in different conditions and different loads.
© A variety of starting ways: voltage ramp starting way can get the maximum output torque; Current limiting can realize biggest limitations of the soft start starting current.
© Reliable quality assurance: using computer simulation design; SMT production process; Excellent electromagnetic compatibility performance;High tSTperature aging, vibration test of the machine before delivery.
© Perfect and reliable protection function: loss of voltage, less voltage, over voltage protection; overheating, starting time too long; Input phase lost, output phase lost, three-phase imbalance; starting over current, overload and load short circuit protection, etc.
© Full dynamic control field-bus monitoring starter, easy networking
© LCD displaying screen can display parameter code, state and error.
Â
Technical specification
Input Voltage | Three-phase 220V/380V/480V/660 AC | ||
Frequency | 50/60Hz | ||
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
Starting Times | It is recommended not to exceed 20 times per hour. | ||
Control Mode |
(1) Operation panel control.   (2) Operation panel + external control. (3) External control. (4) External control + COM control. |
(5) Operation panel + external + COM control. (6) Operation panel + COM control. (7) COM control. (8) No start or stop operation. |
|
Start Mode |
(1) Current-limiting to start. (2) Voltage ramp to start. (3) Torque control + current-limiting to start. |
(4) Torque control + voltage ramp to start. (5) Current ramp to start. (6) Voltage current-limiting double closed-loop start. |
|
Stop Mode | (1) Soft stop. | (2) Free stop. | |
Protective Function |
(1)Open loop protection for external instantaneous stop terminals. (2) Over-heat protection for soft starter. (3) Protection for too long starting time. (4) Input open phase protection. (5) Output open phase protection. (6) Unbalanced three-phase protection. (7) starting over current protection. (8) Running overload protection. (9) Under voltage protection for power voltage. (10) Overvoltage protection for power voltage. (11) Protection for fault parameter setting. (12) Load short circuit protection. (13) Auto restart or incorrect wiring protection. (14)Incorrect wiring protection of external control stop terminals. |
||
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
Altitude | Below 1000M. It have to rise the rate power when the altitude is more than 1000M. | ||
Temperature | -30 +55 oC | ||
Humidity | 90%RH without dew condensation. | ||
Vibration | <0.5G | ||
Structure | Protection Class | IP20 | |
Cooling Pattern | Natural wind cooling. |
Products SelectionÂ
1, 220V SeriesÂ
Â
   Model |  Current     (A) |
Standard   (kW) |
  Heavy load    (kW) |
  Model |  Current   (A) |
Standard   (kW) |
 Heavy load    (kW) |
ST-GS2-5d5 | Â Â 22 | Â Â 5.5 | Â Â Â Â 4 | Â ST-GS2-075 | Â 320 | Â Â 75 | Â Â Â 55 |
ST-GS2-7d5 | Â Â 30 | Â Â 7.5 | Â Â Â Â 5.5 Â | Â ST-GS2-090 | Â 370 | Â Â 90 | Â Â Â 75 |
ST-GS2-011 | Â Â 45 | Â Â 11 | Â Â Â Â 7.5 | Â ST-GS2-115 | Â 400 | Â Â 115 | Â Â Â 90 |
ST-GS2-015 | Â Â 60 | Â Â 15 | Â Â Â Â Â 11 | Â ST-GS2-132 | Â 500 | Â Â 132 | Â Â Â 115 |
ST-GS2-018 | Â Â 75 | Â Â 18.5 | Â Â Â Â Â 15 | Â ST-GS2-160 | Â 560 | Â Â 160 | Â Â Â 132 |
ST-GS2-022 | Â Â 90 | Â Â 22 | Â Â Â Â 18.5 | Â ST-GS2-185 | Â 630 | Â Â 185 | Â Â Â 160 |
ST-GS2-030 | Â Â 110 | Â Â 30 | Â Â Â Â 22 | Â ST-GS2-200 | Â 800 | Â Â 200 | Â Â Â 185 |
ST-GS2-037 | Â Â 150 | Â Â 37 | Â Â Â Â Â 30 | Â ST-GS2-220 | Â 900 | Â Â 220 | Â Â Â 200 |
ST-GS2-045 | Â Â 180 | Â Â 45 | Â Â Â Â Â 37 | Â ST-GS2-250 | Â 1000 | Â Â 250 | Â Â Â 220 |
ST-GS2-055 | Â Â 230 | Â Â 55 | Â Â Â Â Â 45 | Â ST-GS2-280 | Â 1200 | Â Â 280 | Â Â Â 250 |
2, 380V SeriesÂ
Â
   Model |  Current     (A) |
Standard   (kW) |
  Heavy load    (kW) |
  Model |  Current   (A) |
Standard   (kW) |
 Heavy load    (kW) |
ST-GS3-5d5 | Â Â 11 | Â Â 5.5 | Â Â Â Â 4 | Â ST-GS3-132 | Â 260 | Â Â 132 | Â Â Â 115 |
ST-GS3-7d5 | Â Â 15 | Â Â 7.5 | Â Â Â Â 5.5 Â | Â ST-GS3-160 | Â 320 | Â Â 160 | Â Â Â 132 |
ST-GS3-011 | Â Â 23 | Â Â 11 | Â Â Â Â 7.5 | Â ST-GS3-185 | Â 370 | Â Â 185 | Â Â Â Â 160 |
ST-GS3-015 | Â Â 30 | Â Â 15 | Â Â Â Â Â 11 | Â ST-GS3-200 | Â 400 | Â Â Â 200 | Â Â Â 185 |
ST-GS3-018 | Â Â 37 | Â Â 18.5 | Â Â Â Â Â 15 | Â | Â | Â | Â |
ST-GS3-022 | Â Â 45 | Â Â 22 | Â Â Â Â 18.5 | Â ST-GS3-250 | Â 500 | Â Â 250 | Â Â Â 220 |
ST-GS3-030 | Â Â 60 | Â Â 30 | Â Â Â Â 22 | Â ST-GS3-280 | Â 560 | Â Â 280 | Â Â Â 250 |
ST-GS3-037 | Â Â 75 | Â Â 37 | Â Â Â Â Â 30 | Â ST-GS3-320 | Â 630 | Â Â 320 | Â Â Â 280 |
ST-GS3-045 | Â Â 90 | Â Â 45 | Â Â Â Â Â 37 | Â ST-GS3-355 | Â 710 | Â Â 355 | Â Â Â 320 |
ST-GS3-055 | Â Â 110 | Â Â 55 | Â Â Â Â Â 45 | Â ST-GS3-400 | Â 800 | Â Â 400 | Â Â 355 |
ST-GS3-075 | Â Â 150 | Â Â Â 75 | Â Â Â Â 55 | Â ST-GS3-450 | Â 900 | Â Â 450 | Â Â 400 |
ST-GS3-090 | Â Â 180 | Â Â Â Â 90 | Â Â Â Â Â 75 | Â ST-GS3-500 | Â 1000 | Â Â 500 | Â Â 450 |
ST-GS3-115 | Â Â 230 | Â Â Â 115 | Â Â Â Â 90 | Â ST-GS3-600 | Â 1200 | Â Â 600 | Â Â 500 |
3, 480V Series
Â
Model | Current (A) |
Matching motor power | Model | Current (A) |
Matching motor power | ||
Standard (kW) |
Heaavy load (kW) |
Standard (kW) |
Heaavy load (kW) |
||||
ST-GS4-5d5 | 11 | 5.5 | 4 | ST-GS4-132 | 260 | 132 | 115 |
ST-GS4-7d5 | 15 | 7.5 | 5.5 | ST-GS4-160 | 320 | 160 | 132 |
ST-GS4-011 | 23 | 11 | 7.5 | ST-GS4-185 | 370 | 185 | 160 |
ST-GS4-015 | 30 | 15 | 11 | ST-GS4-200 | 400 | 200 | 185 |
ST-GS4-018 | 37 | 18.5 | 15 | ST-GS4-250 | 500 | 250 | 200 |
ST-GS4-022 | 45 | 22 | 18.5 | ST-GS4-280 | 560 | 280 | 250 |
ST-GS4-030 | 60 | 30 | 22 | ST-GS4-320 | 630 | 320 | 280 |
ST-GS4-037 | 75 | 37 | 30 | ST-GS4-355 | 710 | 355 | 320 |
ST-GS4-045 | 90 | 45 | 37 | ST-GS4-400 | 800 | 400 | 355 |
ST-GS4-055 | 110 | 55 | 45 | ST-GS4-450 | 900 | 450 | 400 |
ST-GS4-075 | 150 | 75 | 55 | ST-GS4-500 | 1000 | 500 | 450 |
ST-GS4-090 | 180 | 90 | 75 | ST-GS4-600 | 1200 | 600 | 500 |
ST-GS4-115 | 230 | 115 | 90 | Â | Â | Â | Â |
Size Information
Soft starter installation diagram
The soft start (5.5KW~600KW) selection list of peripheral appliances are as follows:
Â
Model | Rated power (KW) | Rated current (A) | Breaker (A) | By-pass contactor(A) | Cable size (mm2) |
XX-XX3-5d5 | 5.5 | 11 | 16 | 16 | 4 mm2 |
XX-XX3-7d5 | 7.5 | 15 | 20 | 16 | 4 mm2 |
XX-XX3-011 | 11 | 23 | 32 | 25 | 6 mm2 |
XX-XX3-015 | 15 | 30 | 40 | 40 | 10 mm2 |
XX-XX3-018 | 18 | 37 | 50 | 40 | 10 mm2 |
XX-XX3-022 | 22 | 43 | 63 | 63 | 16 mm2 |
XX-XX3-030 | 30 | 60 | 80 | 63 | 25 mm2 |
XX-XX3-037 | 37 | 75 | 100 | 100 | 35 mm2 |
XX-XX3-045 | 45 | 90 | 125 | 100 | 35 mm2 |
XX-XX3-055 | 55 | 110 | 160 | 160 | 35 mm2 |
XX-XX3-075 | 75 | 150 | 180 | 160 | 30×3 mm2 |
XX-XX3-090 | 90 | 180 | 225 | 250 | 30×3 mm2 |
XX-XX3-115 | 115 | 230 | 315 | 250 | 30×3 mm2 |
XX-XX3-132 | 132 | 264 | 315 | 400 | 30×4 mm2 |
XX-XX3-160 | 160 | 320 | 350 | 400 | 30×4 mm2 |
XX-XX3-185 | 185 | 370 | 400 | 400 | 30×4 mm2 |
XX-XX3-200 | 200 | 400 | 400 | 400 | 50×5 mm2 |
XX-XX3-250 | 250 | 500 | 630 | 630 | 50×5 mm2 |
XX-XX3-280 | 280 | 560 | 630 | 630 | 50×5 mm2 |
XX-XX3-320 | 320 | 640 | 630 | 630 | 50×5 mm2 |
XX-XX3-355 | 355 | 710 | 1000 | 1000 | 60×6 mm2 |
XX-XX3-400 | 400 | 800 | 1000 | 1000 | 60×6 mm2 |
XX-XX3-450 | 450 | 900 | 1000 | 1000 | 60×6 mm2 |
XX-XX3-500 | 500 | 1000 | 1250 | 1000 | 80×6 mm2 |
XX-XX3-600 | 600 | 1200 | 1600 | 1600 | 80×6 mm2 |
- The rated power and rated current indicate the maximum rated value of the soft start. The matching specification of breakers and bypass contactors should match with the motor.
- Soft starter is for six terminal inputs and three terminal outputs, it is still with the online protection function at the state of bypass contactor sucking, do not need to add additional motor protection device.
52V 75W/120W POE Switch Power supply for POE injector, high voltage 52 volt 75W/120W power supply
52V 75/ 120W power supply
For POE injector, POE Switch, to power IP camera, IP phone, Access point, powered over ethernet.
Features:
Input voltage range: AC 110V ~ 240V 47-63Hz
Rated output rating: Load regulation: 3-48v±5% 48W Max.
Output no-load voltage: 105% output voltage Max(Nom.)
Inrush current (Cold): 80A Max.
Protection: OCP/ OVP/ SCP
Dielectric strength: Input – Output 3.0 KV for 1 minute
Insulation resistance: 500VDC 50MΩ Mini
Efficiency: 90% Normally @ rated load
Ripple & Noise: 1% output voltage Max.
Line regulation: ±1%
Hold up time: 3ms
Temperature rise: 95 °C Max. @ rated load / Class B
IP Camera, IP phone, WIFI Access Point 802.3 af/at
POE Switch,POE Switches Puzzle,POE Switches 4 Port,POE Switches For Sale
Dongguan Xiaoerduo Electronics Co., Ltd. , http://www.steadysmps.com